Skip to content Skip to footer

ABB SUE3000 1VCF750090R0804 Uninterruptible Power Supply (UPS)

ABB SUE3000 (1VCF750090R0804) — Technical Overview
Product:​ SUE3000 — Uninterruptible Power Supply (UPS)
Manufacturer:​ ABB
Order Code:​ 1VCF750090R0804
Primary Application:​ A three-phase, double-conversion online UPS system​ designed to provide continuous, high-quality, and clean power​ for critical industrial processes, data centers, infrastructure, and large commercial facilities, protecting sensitive loads from all types of power disturbances.
Category: Product ID: 22805

Description

ABB SUE3000 (1VCF750090R0804) — Technical Overview
Product:​ SUE3000 — Uninterruptible Power Supply (UPS)
Manufacturer:​ ABB
Order Code:​ 1VCF750090R0804
Primary Application:​ A three-phase, double-conversion online UPS system​ designed to provide continuous, high-quality, and clean power​ for critical industrial processes, data centers, infrastructure, and large commercial facilities, protecting sensitive loads from all types of power disturbances.

1. Core Overview & Positioning

The ABB SUE3000 is a member of ABB’s premium 3-phase UPS series. It represents a high-end solution for mission-critical applications requiring the highest levels of power availability and system resilience. The specific order code 1VCF750090R0804​ defines this unit’s precise electrical ratings, configuration, and optional features (e.g., power rating in kVA, input/output voltage, battery voltage, communication cards).
Key Technology:​ It utilizes true double-conversion online technology, where the input AC is continuously converted to DC (rectifier), then back to a perfectly regulated and isolated AC output (inverter). This provides complete isolation from all utility power problems including outages, sags, surges, harmonics, and frequency variations.

2. Key Features & Functions

  • Online Double-Conversion:​ Ensures zero transfer time to battery and total isolation of the load from the raw mains.
  • High Efficiency & Eco Mode:​ Features high operational efficiency at typical loads. Often includes an optional Eco Mode​ that allows the load to be fed directly from the filtered mains when power is good, with instantaneous transfer to inverter if needed, to maximize energy savings.
  • Modular & Scalable Design:​ Many models in the SUE3000 series feature a modular architecture, allowing for N+X redundancy​ and hot-swappable power modules​ to increase system availability and simplify maintenance.
  • Wide Input Voltage & Frequency Range:​ Can handle significant grid fluctuations without depleting the battery, thereby extending battery life.
  • Advanced Battery Management (ABM):​ Intelligent charging algorithms to maximize battery performance and lifespan.
  • Comprehensive Communication & Monitoring:​ Standard and optional communication interfaces (Modbus, SNMP, USB, Relay Contacts, Network Cards) for seamless integration into Building Management Systems (BMS), Data Center Infrastructure Management (DCIM), or remote monitoring platforms.
  • Robust Construction:​ Designed for 24/7 operation in demanding environments, often with a high protection class (IP rating) for dust and moisture.
SUE3000

3. Common Technical Specifications (Inferred from Series)

  • Power Range:​ The SUE3000 series typically covers a wide range, often from 10 kVA up to several hundred kVA. The exact rating is encoded in the order number (e.g., 090 might indicate ~90-100 kVA).
  • Input:
    • Voltage:​ 3-phase + Neutral (e.g., 380/400/415V AC).
    • Frequency:​ 50/60 Hz auto-sensing.
  • Output:
    • Voltage:​ Stable 3-phase + Neutral (e.g., 380/400/415V AC).
    • Frequency:​ Stable 50 or 60 Hz.
    • Waveform:​ Pure sine wave.
  • Battery Voltage:​ DC voltage is defined by the order code (e.g., common blocks like 360V DC, 480V DC).
  • Topology:​ Online Double-Conversion (VFI according to IEC 62040-3).
  • Form Factor:​ Tower or rack-mount cabinet.

4. System Integration & Typical Architecture

  • Primary Role:​ Installed between the utility/generator power source and the critical load.
  • Standard Configuration:
    1. Utility/Genset​ -> Input Switchgear​ -> SUE3000 UPS​ -> Output Distribution Panel​ -> Critical Loads.
  • Redundant Configuration:
    • Parallel Systems:​ Multiple SUE3000 units can be paralleled for capacity (N) or redundancy (N+1, N+X).
    • External Maintenance Bypass:​ A static or manual bypass cabinet is always recommended for safe maintenance.
  • Battery System:​ Connected to an external battery cabinet or battery strings sized for the required backup autonomy time.

5. Typical Applications

  • Industrial Process Control:​ Protecting PLCs, DCS systems, and instrumentation in oil & gas, chemical, and manufacturing plants.
  • Data Centers & IT Rooms:​ Providing fault-tolerant power for servers, storage, and network equipment.
  • Critical Infrastructure:​ Airports, transportation control systems, telecom central offices.
  • Healthcare:​ Medical imaging equipment, laboratory systems.
  • Financial Institutions:​ Trading floors, data servers.