Description
GE DS200TB.QAG1A — Terminal Board / I/O Interface Module
Product: DS200TBQAG1A, Terminal Board Assembly
Manufacturer: GE (General Electric), part of the Mark VI / Mark VIe Speedtronic Turbine Control System family.
Primary Application: A terminal board (I/O interface module) used within GE’s Mark VI and Mark VIe control systems for signal conditioning, isolation, and termination of field wiring connected to the turbine control system.
1. Core Overview & System Context
The DS200TBQAG1A is a critical interface component in GE’s Speedtronic turbine control platform. The «DS200» prefix identifies it as part of the Drive System 200 series, which encompasses a wide range of I/O, power, and control modules for the Mark VI system.
Key Function: It serves as a passive or semi-passive termination and distribution point. Its primary roles are to:
-
Provide secure, high-quality screw terminals for field wiring (from sensors, switches, transmitters, actuators).
-
Offer signal conditioning, such as fusing, isolation, or conversion for specific signal types.
-
Route these conditioned signals via internal connectors or a backplane to the primary control or I/O processing boards (e.g., DS200DCFG, DS200DIOB cards).
2. Key Features & Functions
-
Field Wiring Termination: Provides robust screw terminal blocks for reliable connection of field device wires, reducing stress on the more delicate connectors of the active control boards.
-
Signal Conditioning & Protection (Model Dependent): May include:
-
Fuses or Resistors: For current limiting on analog or digital inputs.
-
Isolation Barriers: Galvanic isolation between field and control sides for noise immunity and safety.
-
Surge Protection: Transient voltage suppression for signals in electrically noisy environments.
-
-
Signal Routing: Channels multiple field signals to the correct pins of a mating connector that plugs into an active I/O card or the system backplane.
-
Status Indication: May include LED indicators for specific channels (e.g., power presence, fault status).

3. Common Technical Specifications
-
Part Number Breakdown:
-
DS200: Drive System 200 series.
-
TBQ: Indicates a specific Terminal Board model series. «Q» often relates to the board’s function or the type of signals it handles (e.g., specific to certain analog/digital groups).
-
A: Hardware revision or variant.
-
G1: Generation 1 hardware.
-
A: Final suffix, often indicating a specific configuration or approval variant.
-
-
Form Factor: A printed circuit board (PCB) assembly with terminal blocks, designed to mount in a Mark VI I/O pack or terminal enclosure.
-
Connections: High-density screw terminal blocks on one side, and one or more multi-pin connectors (e.g., DIN type) on the other for connection to the system.
-
Compatibility: Designed to work in conjunction with specific Mark VI I/O packs (e.g., TBCI, TBQC, TBQA frames) and mate with corresponding I/O processor cards.
4. System Integration
-
Location: Installed within a designated slot of a Mark VI Terminal Board I/O Pack. These packs are distributed around the turbine and connect via network (e.g., PDH, UDH) to the main controllers.
-
Role in Signal Chain:
-
Field Device (e.g., thermocouple, pressure switch) wires directly to the terminal block on the DS200TBQAG1A.
-
The board conditions/protects the signal and routes it internally.
-
The signal passes via a connector to a daughter card or I/O processor card (e.g., a digital input card) housed in the same I/O pack.
-
The I/O processor card digitizes the signal and communicates it to the Mark VI Controller over the control network.
-
-
Maintenance: Designed to simplify wiring and maintenance. The terminal board can often be replaced without disturbing the field wiring if the same type is used.
5. Typical Applications
Used throughout a GE turbine (gas or steam) control system for interfacing with hundreds of field devices:
-
Analog Input Termination: For 4-20mA transmitters (pressure, temperature, flow).
-
Digital Input Termination: For contact closures from switches (limit switches, pressure switches, pushbuttons).
-
Digital Output Termination: For signals driving relays, solenoid valves, or indicators.
-
Thermocouple/RTD Termination: Direct connection of temperature sensors (if equipped with appropriate conditioning).

Reviews