ABB GF D563 A101 3BHE046836R0101 Digital Generator Protection Relay

ABB GF D563 A101 (3BHE046836R0101) — Generator Protection Relay
Product:​ GF D563 A101, Digital Generator Protection Relay
Order Code:​ 3BHE046836R0101
Manufacturer:​ ABB
Primary Application:​ A numerical generator protection relay​ designed for comprehensive protection, control, and monitoring of medium to large generators​ (hydro, steam, gas, combined-cycle) in utility, industrial, and independent power plants. Part of ABB’s Relion® 650 series protection platform.
Category: Product ID: 22843

Description

ABB GF D563 A101 (3BHE046836R0101) — Generator Protection Relay
Product:​ GF D563 A101, Digital Generator Protection Relay
Order Code:​ 3BHE046836R0101
Manufacturer:​ ABB
Primary Application:​ A numerical generator protection relay​ designed for comprehensive protection, control, and monitoring of medium to large generators​ (hydro, steam, gas, combined-cycle) in utility, industrial, and independent power plants. Part of ABB’s Relion® 650 series protection platform.

1. Core Overview & Positioning

The ABB GF D563 A101 is a member of ABB’s Relion® 650 series​ protection relay family, specifically configured for generator protection applications. The «GF» designation indicates its specialization in Generator and Feeder​ protection functions. It consolidates multiple protection, control, and monitoring functions into a single intelligent electronic device (IED), replacing numerous discrete relays and meters.
Key Philosophy:​ Provides complete generator management with advanced protection algorithms, extensive metering, and flexible communication options, ensuring maximum equipment protection, availability, and grid code compliance.

2. Key Protection & Control Functions

  • Generator Differential Protection (87G):​ High-speed unit protection for stator winding faults.
  • Stator Ground Fault Protection (64G1, 64G2):​ Sensitive protection for stator earth faults using neutral voltage displacement and injection methods.
  • Loss of Excitation (40):​ Protection against generator under-excitation conditions.
  • Negative Sequence/Unbalance Protection (46):​ Protection against rotor overheating due to unbalanced stator currents.
  • Overexcitation Protection (24):​ V/Hz protection for generator and step-up transformer.
  • Out-of-Step Protection (78):​ Detects pole slipping and unstable power swings.
  • Voltage/Frequency Protection (27, 59, 81):​ Comprehensive voltage and frequency protection.
  • Breaker Failure Protection (50BF):​ Backup protection for circuit breaker failures.
  • Automatic Voltage Regulator (AVR) Interface:​ For excitation system control and protection.
  • Programmable Logic (CFC):​ Configurable Function Chart editor for custom control schemes without external PLCs.
GF D563 | 3BHE046836R0101

3. Model Number Breakdown & Specifications

Typical Technical Specifications:
  • Current Inputs:​ 5A or 1A nominal (configurable)
  • Voltage Inputs:​ Up to 300V AC L-L (via VTs)
  • Auxiliary Supply:​ 48-250V DC/AC
  • Communication Interfaces:
    • Ethernet ports (IEC 61850, Modbus TCP)
    • Serial ports (RS485, IEC 60870-5-103)
    • Fiber optic ports for line differential protection
  • I/O Capacity:​ Extensive binary inputs/outputs
  • Measurement Accuracy:​ Better than 0.5% for current/voltage
  • Operation Time:​ < 20 ms for most protection functions
  • Certifications:​ IEC 60255, IEEE C37.90, ANSI standards

4. System Integration & Engineering

  • Protection Scheme Integration:
    • Interfaces with generator CTs and VTs
    • Connects to generator circuit breaker trip coils
    • Interfaces with excitation system (AVR)
    • Communicates with plant DCS/SCADA
  • Engineering Tools:​ Configured using ABB’s PCM600​ protection and control IED manager
  • Communication Protocols:
    • IEC 61850-8-1 (MMS/GOOSE)
    • IEC 61850-9-2 LE (Sampled Values)
    • DNP3.0, Modbus, IEC 60870-5-103/104
  • Redundancy Support:​ Can be configured in redundant schemes for critical applications

5. Typical Applications

  • Utility Power Plants:​ Protection of large steam and gas turbine generators
  • Hydroelectric Plants:​ Generator and generator-transformer protection
  • Industrial Plants:​ Cogeneration and captive power plant protection
  • Wind Farms:​ Large wind turbine generator protection
  • Peaking Plants:​ Fast-start generator protection