Skip to content Skip to footer

DATEL ICP232.2-5V 029.361114

Parameter Name
Parameter Value
Product Model
DATEL ICP232.2-5V 029.361114
Manufacturer
DATEL (or a manufacturer specializing in measurement transducers)
Product Type
Hall Effect Split-Core Current Transducer / Clamp-on Current Probe
Primary Current (Ipn)
Likely a nominal range such as 0-200A AC/DC​ or 0-300A AC/DC​ (specific to 232.2 model). Has a maximum overload capacity.
Output Signal
0-5V DC​ output, proportional to the primary current. Typically, 0A corresponds to 0V or 2.5V (offset), and the full-scale primary current corresponds to 5V. Requires an external power supply.
Category: Product ID: 23421

Description

Product Overview

The DATEL ICP232.2-5V 029.361114​ is a high-precision, Industrial Current Probe​ (ICP) designed for non-invasive measurement of AC and DC currents. This device belongs to the category of clamp meters​ or current transducers​ that utilize the Hall effect principle. Its primary function is to convert a primary current flowing through a conductor into a proportional, isolated, and low-voltage output signal, typically 0-5V DC. The «232.2» likely denotes its current measurement range (e.g., 0 to 200A or 300A), and «-5V» specifies its output as a 0-5V DC signal. The suffix 029.361114is a specific part or order number. The probe features a split-core or clamp-on design, allowing it to be easily installed around an existing conductor without breaking the circuit, making it ideal for monitoring, data logging, and control applications in industrial, energy management, and automation systems.
The core value of the DATEL ICP232.2-5V​ lies in its safety, accuracy, and ease of installation. By providing galvanic isolation between the measured high-current circuit and the measurement/control system, it eliminates the risks associated with direct electrical connections, protecting personnel and sensitive equipment like PLCs, DCS analog input cards, or data loggers. Its Hall effect technology allows it to measure both AC and DC currents with good accuracy and linearity. The clamp-on design enables quick deployment and retrofit into existing panels without shutdowns. For engineers and technicians involved in power monitoring, motor load analysis, energy audits, or equipment protection, this current probe offers a reliable and convenient method to obtain accurate current data, which is fundamental for performance analysis, predictive maintenance, and system optimization.

Technical Specifications

Parameter Name
Parameter Value
Product Model
DATEL ICP232.2-5V 029.361114
Manufacturer
DATEL (or a manufacturer specializing in measurement transducers)
Product Type
Hall Effect Split-Core Current Transducer / Clamp-on Current Probe
Primary Current (Ipn)
Likely a nominal range such as 0-200A AC/DC​ or 0-300A AC/DC​ (specific to 232.2 model). Has a maximum overload capacity.
Output Signal
0-5V DC​ output, proportional to the primary current. Typically, 0A corresponds to 0V or 2.5V (offset), and the full-scale primary current corresponds to 5V. Requires an external power supply.
Power Supply
Requires a dual or single DC supply voltage to operate the internal electronics, common ratings are ±12V DC to ±15V DC​ or a single +12V/+24V DC, depending on the model.
Accuracy
Good accuracy, typically in the range of ±1% of reading​ or better at 25°C, depending on the model variant.
Linearity
Excellent linearity over the measurement range.
Frequency Bandwidth
Suitable for measuring power frequency currents (50/60 Hz) and may have a bandwidth extending to a few kHz for harmonic analysis.
Isolation
High isolation voltage between the primary conductor (high voltage/current) and the secondary output/electronics, typically several kV.
Opening Mechanism
Split-core (clamp) design for easy installation around the conductor.
Conductor Size
Accommodates a maximum conductor diameter (e.g., up to 30mm).
Operating Temperature
Industrial temperature range, e.g., -25°C to +70°C.
Response Time
Fast response time, suitable for dynamic load monitoring.
Certifications
May carry CE, cULus, or other safety and EMC certifications.
ICP232 029.359 325

Key Features and Advantages

DATEL ICP232.2-5V 029.361114​ excels through its non-invasive measurement and versatility. Its primary advantage is the split-core, clamp-on design, which allows for quick, safe, and hassle-free installation on live conductors without the need for costly shutdowns or splicing into existing wiring. This makes it perfect for temporary diagnostics, retrofitting monitoring into existing systems, or permanent installations where isolation is paramount. The ability to measure both AC and DC currents​ with a single device adds significant flexibility compared to traditional current transformers (CTs), which are AC-only.
High accuracy, isolation, and signal integrity​ are hallmarks of its design. Utilizing Hall effect technology, it provides a voltage output that is linearly proportional to the measured current, with good accuracy across a wide temperature range. The built-in galvanic isolation​ is a critical safety feature, completely separating the measurement circuit from the potentially hazardous primary circuit. The 0-5V DC output is a standard industrial signal level, making it directly compatible with a vast array of data acquisition systems, PLC analog input modules, chart recorders, and SCADA systems without additional signal conditioning.
Robust construction and reliability​ ensure long-term performance in industrial environments. Housed in a rugged, often plastic or composite casing, it is designed to withstand vibration, dust, and moisture. The clear marking of the current direction and the secure latching mechanism ensure correct and reliable installation. For system integrators, the ICP232.2-5V​ provides a trusted, off-the-shelf solution for current measurement that simplifies design, enhances safety, and delivers the accurate data needed for energy management, load profiling, and equipment protection strategies.

Application Areas

The DATEL ICP232.2-5V​ current probe is used in a wide variety of applications where non-invasive current measurement is required.
Typical applications include:
  • Industrial Motor Load Monitoring:​ Measuring current to assess motor health, efficiency, and to detect overload or underload conditions on pumps, fans, and compressors.
  • Energy Management Systems (EMS):​ Sub-metering of electrical loads for cost allocation, identifying energy-saving opportunities, and verifying equipment performance.
  • Variable Frequency Drive (VFD) Input/Output Monitoring:​ Measuring current on both the line and motor side of drives.
  • UPS and Battery System Monitoring:​ Measuring DC battery charge/discharge currents.
  • Renewable Energy Systems:​ Monitoring inverter output or PV string currents.
  • Power Quality Analysis:​ Capturing current waveforms for harmonic analysis alongside voltage probes.
Essentially, it is applied anywhere there is a need to safely and accurately measure the current in a conductor for monitoring, control, or diagnostic purposes, particularly in retrofit situations or where electrical isolation is a strict requirement.

Related Products

  • Data Acquisition Systems (DAQ) or PLC Analog Input Cards:​ The systems that read the 0-5V output signal from the probe.
  • External DC Power Supply:​ To provide the required operating voltage (e.g., ±12V) to the transducer.
  • Signal Conditioners/Isolators:​ May be used if further signal processing or isolation is required, though the probe itself provides isolation.
  • Panel-Mount Display Meters:​ To locally show the measured current value.
  • Current Transformers (CTs):​ AC-only alternatives for fixed installations where breaking the conductor is acceptable.
  • Voltage Transducers/Probes:​ For simultaneous voltage and power measurements.

Reviews

There are no reviews yet.

Be the first to review “DATEL ICP232.2-5V 029.361114”

Ваш адрес email не будет опубликован. Обязательные поля помечены *