GE SR745-W3-P5-G5-HI-ALR-E-H Transformer Protection Relay

GE SR745-W3-P5-G5-HI-ALR-E-H — Transformer Protection Relay
Product:​ SR745-W3-P5-G5-HI-ALR-E-H, Numerical Transformer Protection Relay
Manufacturer:GE (General Electric)​ — now part of GE Vernova (Grid Solutions)
Product Line:Multilin 745 Series
Primary Application:​ A comprehensive numerical protection relay​ specifically designed for the protection, control, and monitoring of two-winding power transformers​ in utility substations, industrial plants, and renewable energy installations.
Category: Product ID: 22861

Description

GE SR745-W3-P5-G5-HI-ALR-E-H — Transformer Protection Relay
Product:​ SR745-W3-P5-G5-HI-ALR-E-H, Numerical Transformer Protection Relay
Manufacturer:GE (General Electric)​ — now part of GE Vernova (Grid Solutions)
Product Line:Multilin 745 Series
Primary Application:​ A comprehensive numerical protection relay​ specifically designed for the protection, control, and monitoring of two-winding power transformers​ in utility substations, industrial plants, and renewable energy installations.

1. Core Overview & Positioning

The GE Multilin SR745 is a sophisticated numerical relay engineered specifically for power transformer management. The extended order code «SR745-W3-P5-G5-HI-ALR-E-H» defines the exact hardware configuration, communication options, and feature set for this unit. It integrates multiple protection functions, advanced monitoring, and control capabilities into a single device, replacing numerous discrete relays and meters.
Key Value:​ It provides complete transformer management with advanced protection algorithms, extensive metering, and flexible communication options, ensuring maximum equipment protection, availability, and grid code compliance.

2. Key Protection & Control Functions

  • Transformer Differential Protection (87T):​ Percentage-restrained, dual-slope differential protection as the primary scheme, with 2nd and 5th harmonic blocking/restraint for secure operation during transformer inrush and overexcitation.
  • Restricted Earth Fault (64REF):​ High-sensitivity ground fault protection for the transformer windings.
  • Overcurrent Protection:
    • Phase Time Overcurrent (51) and Instantaneous (50).
    • Ground Time Overcurrent (51N/G) and Instantaneous (50N/G).
    • Neutral Time Overcurrent (51N).
  • Transformer-Specific Protection:
    • Thermal Overload (49):​ Implements a dual-time constant thermal model (IEEE/ANSI) to protect the transformer from overheating damage.
    • Overexcitation (Volts/Hertz) Protection (24).
    • Over/Under Voltage (59/27)​ and Frequency (81O/U)​ protection.
  • Control & Automation:
    • Breaker Failure Protection (50BF).
    • Programmable Logic (FlexLogic™):​ Allows creation of custom control schemes, interlocking, and automation sequences without external hardware.
    • Multiple Setpoint Groups:​ For changing protection settings based on topology (e.g., different settings for different tap positions or system configurations).
SR745-W2-P1-G1-HI-A-L-R

3. Monitoring, Metering & Diagnostics

  • Comprehensive Measurement:​ All phase currents and voltages, sequence components, real/reactive/apparent power (P, Q, S), power factor, frequency, and energy (kWh, kVArh) with pulse outputs.
  • Disturbance & Event Recording:​ High-resolution oscillographic fault recording (COMTRADE format) and time-stamped event logs for post-mortem analysis.
  • Transformer Monitoring:​ Can interface with RTDs (via optional module) for direct winding and oil temperature monitoring, and calculate a simulated hotspot temperature.
  • Advanced Diagnostics:​ Continuous self-diagnostics for hardware and software integrity.

4. System Integration

  • Engineering Tools:​ Configured using GE’s Enervista UR Setup​ software. All protection settings, FlexLogic™ schemes, and communication mapping are defined here.
  • Communication:​ Acts as an IEC 61850 Intelligent Electronic Device (IED)​ on the substation LAN. It reports to SCADA via IEC 61850 MMS or DNP3.0, and can exchange high-speed peer-to-peer signals using GOOSE​ for interlocking or breaker failure schemes.
  • Wiring:​ Connects directly to transformer HV and LV side CTs​ (5A as per P5), voltage transformers (VTs), and the circuit breaker trip/close circuits via its output relays (G5).

5. Typical Applications

  • Utility Substations:​ Protection of step-up (generator) and step-down (distribution) transformers.
  • Industrial Plants:​ Primary protection for main plant transformers and large process transformers.
  • Renewable Energy:​ Protection of the main power transformer in wind farms or solar PV plants.
  • Autotransformers:​ Can be applied with appropriate configuration and careful consideration of the common winding.