ABB PPD517 3BHE0741576R3011​ Multifunctional Voltage Protection Relay

ABB PPD517 (3BHE0741576R3011) — Voltage Protection Relay
Product:​ PPD517 — Multifunctional Voltage Protection Relay
Order Code:​ 3BHE0741576R3011
Manufacturer:​ ABB
Primary Application:​ A numerical protection relay​ designed for comprehensive voltage and frequency protection​ of generators, motors, transformers, busbars, and feeders in medium and high-voltage electrical networks. It is part of ABB’s Relion® protection relay series.
Category: Product ID: 22825

Description

ABB PPD517 (3BHE0741576R3011) — Voltage Protection Relay
Product:​ PPD517 — Multifunctional Voltage Protection Relay
Order Code:​ 3BHE0741576R3011
Manufacturer:​ ABB
Primary Application:​ A numerical protection relay​ designed for comprehensive voltage and frequency protection​ of generators, motors, transformers, busbars, and feeders in medium and high-voltage electrical networks. It is part of ABB’s Relion® protection relay series.

1. Core Overview & Positioning

The ABB PPD517 is a dedicated protection relay focused on voltage and frequency-related faults. It is engineered to safeguard electrical equipment from damage caused by abnormal voltage conditions (overvoltage, undervoltage, voltage unbalance) and frequency deviations (over/under frequency). The order code 3BHE0741576R3011specifies the exact hardware configuration, including voltage ratings, I/O options, and communication protocols.
Key Philosophy:​ It provides reliable, selective, and fast protection against network disturbances that can lead to equipment overheating, instability, or failure, while offering advanced monitoring and control features.

2. Key Protection & Control Functions

  • Voltage Protection:
    • Overvoltage (59):​ Protects against sustained high voltage, which can damage insulation.
    • Undervoltage (27):​ Protects against low voltage, which can cause motors to overcurrent and stall.
    • Negative Sequence / Voltage Unbalance (47):​ Protects generators and motors from overheating due to unbalanced supply (e.g., from single-phase faults).
    • Residual Overvoltage (59N):​ Detects earth faults in isolated or compensated neutral systems.
    • Voltage Differential (27/59):​ For busbar or transformer protection.
  • Frequency Protection:
    • Overfrequency (81O) & Underfrequency (81U):​ Protects generators and loads from damage or instability caused by deviations from nominal frequency (e.g., 50/60 Hz).
    • Rate-of-Change of Frequency (81R):​ Detects severe system imbalances (e.g., sudden loss of generation) for fast load shedding.
  • Additional Functions:
    • Auto-reclosing (79):​ For overhead lines.
    • Synchrocheck (25):​ Ensures safe synchronization of two voltage sources.
    • Multipurpose Protection:​ Configurable stages for other needs (e.g., thermal overload, power protection).
    • Control & Automation:​ Programmable logic (CFC) for custom sequences, breaker control, and interlocking.
  • Measurement & Monitoring:​ Provides comprehensive metering (V, I, P, Q, S, PF, frequency, harmonics, energy) and detailed event recording.
PPD517A3011 3BHE041576R3011

3. Technical Specifications (Based on Order Code)

  • Rated Input:
    • Voltage:​ Defined by order code. Common ranges: R3likely indicates 3-phase voltage input with a nominal voltage (e.g., 110/120V or 220/240V) via potential transformers (PTs/VTs).
    • Current (Optional):​ May include current inputs for power and directional element calculations.
  • Power Supply:​ Typically a wide-range DC or AC supply (e.g., 24-48/60 V DC, 110-230 V AC/DC).
  • Communication:​ Standard features include:
    • IEC 61850​ (Station bus: MMS/GOOSE; Process bus: Sampled Values).
    • Modbus (RTU over RS-485 or TCP/IP over Ethernet).
    • DNP3.0​ and IEC 60870-5-103/104​ protocols.
  • I/O (Binary Inputs/Outputs):​ A configurable number of opto-isolated binary inputs and relay outputs for alarms, trips, and control.
  • Housing:​ Compact, modular case for panel mounting (e.g., 1/2 or 1/4 19-inch rack).

4. Part Number Breakdown: 3BHE0741576R3011

  • 3BHE:​ Standard ABB prefix for protection and control products.
  • 0741576:​ Core product ID for the PPD517 relay.
  • R3011:Configuration suffix​ defining:
    • R3:​ Voltage input configuration (3-phase, 3-wire or 4-wire, specific VT secondary voltage).
    • 011:​ Package of I/O counts, communication ports, power supply, and other hardware options (e.g., number of binary inputs/outputs, type of Ethernet ports, presence of a rear communication port).

5. System Integration & Engineering

  • Role:​ Installed in switchgear panels for protection of incoming feeders, bus sections, transformers, or generators.
  • Wiring:​ Connects to Potential Transformers (PTs/VTs)​ for voltage measurement and optionally to Current Transformers (CTs). Its output relays connect to circuit breaker trip coils.
  • Configuration:​ Fully programmable using ABB’s PCM600​ or Relion® 5xx series commissioning tool. Engineers set protection parameters (pick-up values, time delays, curves), logic, and communication mapping.
  • Integration:​ Communicates with station SCADA, local HMI, or a Bay Control Unit (BCU) via IEC 61850 or other protocols, providing real-time data, alarms, and remote control capability.

6. Typical Applications

  • Generator Protection:​ Backup protection for over/under voltage and frequency.
  • Transformer Protection:​ LV/HV side voltage protection, overexcitation (V/Hz) protection.
  • Busbar Protection:​ Voltage-based schemes (e.g., check synchronizing, busbar undervoltage).
  • Feeder Protection:​ For lines where voltage protection is a primary concern.
  • Load Shedding Schemes:​ Underfrequency and rate-of-change of frequency protection for system stability.
  • Industrial Plants:​ Protection of large motors and process buses.