ABB PPD517 (3BHE0741576R3011) — Voltage Protection Relay
Product: PPD517 — Multifunctional Voltage Protection Relay
Order Code: 3BHE0741576R3011
Manufacturer: ABB
Primary Application: A numerical protection relay designed for comprehensive voltage and frequency protection of generators, motors, transformers, busbars, and feeders in medium and high-voltage electrical networks. It is part of ABB’s Relion® protection relay series.
1. Core Overview & Positioning
The ABB PPD517 is a dedicated protection relay focused on voltage and frequency-related faults. It is engineered to safeguard electrical equipment from damage caused by abnormal voltage conditions (overvoltage, undervoltage, voltage unbalance) and frequency deviations (over/under frequency). The order code
3BHE0741576R3011specifies the exact hardware configuration, including voltage ratings, I/O options, and communication protocols.Key Philosophy: It provides reliable, selective, and fast protection against network disturbances that can lead to equipment overheating, instability, or failure, while offering advanced monitoring and control features.
2. Key Protection & Control Functions
-
Voltage Protection:
-
Overvoltage (59): Protects against sustained high voltage, which can damage insulation.
-
Undervoltage (27): Protects against low voltage, which can cause motors to overcurrent and stall.
-
Negative Sequence / Voltage Unbalance (47): Protects generators and motors from overheating due to unbalanced supply (e.g., from single-phase faults).
-
Residual Overvoltage (59N): Detects earth faults in isolated or compensated neutral systems.
-
Voltage Differential (27/59): For busbar or transformer protection.
-
-
Frequency Protection:
-
Overfrequency (81O) & Underfrequency (81U): Protects generators and loads from damage or instability caused by deviations from nominal frequency (e.g., 50/60 Hz).
-
Rate-of-Change of Frequency (81R): Detects severe system imbalances (e.g., sudden loss of generation) for fast load shedding.
-
-
Additional Functions:
-
Auto-reclosing (79): For overhead lines.
-
Synchrocheck (25): Ensures safe synchronization of two voltage sources.
-
Multipurpose Protection: Configurable stages for other needs (e.g., thermal overload, power protection).
-
Control & Automation: Programmable logic (CFC) for custom sequences, breaker control, and interlocking.
-
-
Measurement & Monitoring: Provides comprehensive metering (V, I, P, Q, S, PF, frequency, harmonics, energy) and detailed event recording.

3. Technical Specifications (Based on Order Code)
-
Rated Input:
-
Voltage: Defined by order code. Common ranges:
R3likely indicates 3-phase voltage input with a nominal voltage (e.g., 110/120V or 220/240V) via potential transformers (PTs/VTs). -
Current (Optional): May include current inputs for power and directional element calculations.
-
-
Power Supply: Typically a wide-range DC or AC supply (e.g., 24-48/60 V DC, 110-230 V AC/DC).
-
Communication: Standard features include:
-
IEC 61850 (Station bus: MMS/GOOSE; Process bus: Sampled Values).
-
Modbus (RTU over RS-485 or TCP/IP over Ethernet).
-
DNP3.0 and IEC 60870-5-103/104 protocols.
-
-
I/O (Binary Inputs/Outputs): A configurable number of opto-isolated binary inputs and relay outputs for alarms, trips, and control.
-
Housing: Compact, modular case for panel mounting (e.g., 1/2 or 1/4 19-inch rack).
4. Part Number Breakdown: 3BHE0741576R3011
-
3BHE: Standard ABB prefix for protection and control products.
-
0741576: Core product ID for the PPD517 relay.
-
R3011: Configuration suffix defining:
-
R3: Voltage input configuration (3-phase, 3-wire or 4-wire, specific VT secondary voltage).
-
011: Package of I/O counts, communication ports, power supply, and other hardware options (e.g., number of binary inputs/outputs, type of Ethernet ports, presence of a rear communication port).
-
5. System Integration & Engineering
-
Role: Installed in switchgear panels for protection of incoming feeders, bus sections, transformers, or generators.
-
Wiring: Connects to Potential Transformers (PTs/VTs) for voltage measurement and optionally to Current Transformers (CTs). Its output relays connect to circuit breaker trip coils.
-
Configuration: Fully programmable using ABB’s PCM600 or Relion® 5xx series commissioning tool. Engineers set protection parameters (pick-up values, time delays, curves), logic, and communication mapping.
-
Integration: Communicates with station SCADA, local HMI, or a Bay Control Unit (BCU) via IEC 61850 or other protocols, providing real-time data, alarms, and remote control capability.
6. Typical Applications
-
Generator Protection: Backup protection for over/under voltage and frequency.
-
Transformer Protection: LV/HV side voltage protection, overexcitation (V/Hz) protection.
-
Busbar Protection: Voltage-based schemes (e.g., check synchronizing, busbar undervoltage).
-
Feeder Protection: For lines where voltage protection is a primary concern.
-
Load Shedding Schemes: Underfrequency and rate-of-change of frequency protection for system stability.
-
Industrial Plants: Protection of large motors and process buses.