Woodward ProTech-Gll 8237-1598 Overspeed Protection System

Woodward ProTech-GII 8237-1598 — Overspeed Protection System
Product:​ ProTech-GII, Model 8237-1598
Manufacturer:​ Woodward, Inc.
Primary Application:​ A triple-redundant (TMR) overspeed protection system​ designed to provide ultra-reliable, failsafe protection against catastrophic overspeed events​ in gas turbines, steam turbines, and large industrial turbines. It is the last line of defense​ for turbine mechanical integrity.
Category: Product ID: 22804

Description

Woodward ProTech-GII 8237-1598 — Overspeed Protection System
Product:​ ProTech-GII, Model 8237-1598
Manufacturer:​ Woodward, Inc.
Primary Application:​ A triple-redundant (TMR) overspeed protection system​ designed to provide ultra-reliable, failsafe protection against catastrophic overspeed events​ in gas turbines, steam turbines, and large industrial turbines. It is the last line of defense​ for turbine mechanical integrity.

1. Core Overview & Positioning

The Woodward ProTech-GII (Generation II) is a dedicated, high-integrity safety system. The model 8237-1598​ is a specific configuration within this line. Its sole, critical purpose is to continuously monitor turbine speed​ and, if a pre-set overspeed trip threshold is reached or exceeded, to initiate an immediate and irreversible shutdown​ by cutting off the fuel supply or actuating stop valves.
Safety Philosophy:​ It operates on a 2-out-of-3 (2oo3) voting logic​ using three independent speed-sensing and processing channels. This Triple Modular Redundant (TMR) architecture ensures:
  • High Availability:​ A single channel failure does not cause a nuisance trip.
  • High Safety (Failsafe):​ The system can still trip safely on a single valid overspeed signal even if another channel has failed.
  • It is typically certified for SIL 2 or SIL 3​ applications per IEC 61508/61511 standards.

2. Key Features & Functions

  • Triple-Redundant Architecture:​ Three completely independent speed sensing inputs, signal conditioning paths, and voting processors.
  • Independent Speed Sensing:​ Accepts signals from three magnetic pickups (MPUs)​ observing a gear or notched wheel on the turbine shaft. This provides true sensor redundancy.
  • 2-out-of-3 Voting Logic:​ The final trip decision requires agreement from at least two of the three channels, preventing both dangerous failures and spurious trips.
  • Dynamic Self-Testing & Diagnostics:​ Continuously performs online diagnostics on each channel’s hardware and software integrity. Faults are annunciated early for preventive maintenance.
  • Independent, Redundant Trip Outputs:​ Provides multiple, physically isolated relay outputs to actuate the turbine’s emergency shutdown solenoids or trip valves.
  • Secure Design:​ Tamper-resistant front cover and password-protected configuration to prevent unauthorized changes to critical trip setpoints.
  • Event Recording:​ Stores detailed event logs and a snapshot of speed traces leading up to and during a trip for forensic analysis.
8237-1600

3. Common Technical Specifications (Model 8237-1598)

  • Speed Inputs:​ Three channels, accepting signals from passive magnetic pickups (MPUs). Typical frequency range up to 20 kHz.
  • Trip Setpoint Accuracy:​ Extremely high (e.g., ±0.1% of setpoint or better).
  • Response Time:​ Extremely fast, typically <10 ms from overspeed detection to output relay actuation.
  • Output Relays:​ Multiple Form-C relay contacts rated for the turbine’s shutdown circuit voltage/current.
  • Power Supply:​ Designed for redundant and isolated DC power supplies (e.g., 24-48 V DC) to further enhance reliability.
  • Communications:​ Includes serial (RS-232/485) or Ethernet ports for integration with the turbine control system (e.g., Woodward NetCon) for monitoring, diagnostics, and event retrieval. Crucially, trip setpoints cannot be changed via this link.
  • Display:​ Front-panel display for viewing speed, status, and diagnostics. Configuration requires a security key or password.

4. System Integration

  • Role:​ It is a separate, dedicated system​ that operates in parallel to the primary turbine control system (e.g., Woodward 505 or NetCon). The primary governor controls normal speed; the ProTech-GII is the independent safety guardian.
  • Installation:​ Mounted in the turbine control panel. Its three MPU sensors are installed on the turbine casing, observing the same wheel but ideally spaced apart.
  • Wiring:​ Inputs from the three MPUs are routed via separate, shielded cables. Output relays are wired in series with the turbine’s master fuel trip circuit.
  • Bypass:​ Has a maintenance bypass​ function for testing, which is strictly controlled and logged.

5. Typical Applications

  • Industrial & Aeroderivative Gas Turbines​ for power generation and mechanical drive.
  • Steam Turbines​ in power plants and industrial facilities.
  • Large Compression Trains​ driven by turbines.
  • Any rotating machinery where a failure due to overspeed would be catastrophic.